YOUR RAISED ACCESS FLOOR SUPPLIER
We have a professional manufacture department and sales team that represents our vision, our determination, passion and desire to make our business grow and help our customers succeed in industry.
Our custom raised access floor options are developed in our plant which helps us reduce cost and increase delivery of quality finished products.
About LY Raised Access Floor Manufacturer
Your Expert Raised Access Floor Manufacturer
- There are many types of raised floor products that can be used in different places.
- Our comapny provide OEM services with your LOGO.
- Free samples are available in custom design and packaging.
- Has rich installation experience,perform raised floor installation projects in various places.
- We have super productivity and can ship in the shortest time.7-30 days after receiving the prepayment.
LY Floor as a raised access flooring manufacturer covers an 140,000 square meters area with around 300+ employee working in our factory. Our annual production capacity for various raised access flooring products can be up to 3 million square meters.
We are designed to meet international standards and is lSO9001 certified, demonstrating their commitment to quality management practices. With years of experience in the industry, Ly has developed a reputation for providing innovative and reliable solutions to meet the needs of their customers.
Raised Floor Products
Choose concrete-filled steel, hollow steel, wood core, aluminum, or perforated raised-floor systems, with HPL, carpet, and bare-steel finish options.
New Access Flooring
New raised-floor systems are available in concrete-filled steel, hollow steel, wood core, and aluminum constructions—built to create more flexible, efficient workspaces.
Pre-Owned Raised Access Flooring
Pre-owned access flooring provides a cost-effective option. Panels can be inspected, cleaned, packaged, and supplied in refurbished or re-laminated configurations.
Tate Access Floors
Source new or pre-owned Tate panels and complete access-floor systems for replacement projects, expansions, and system matching.
Universal High Output Airflow Panels
High-output airflow panels support data-center cooling by directing a greater volume of conditioned air through the floor where it is needed.
Perforated Raised Floor Tiles
Perforated tiles support controlled downflow air distribution and are available in different open-area ratios for cooling requirements.
Computer Floor Replacement Panels
Identify your existing floor system and compare compatible new and pre-owned replacement-panel options.
Access Flooring Systems Disposal
Get assistance identifying, recovering, or disposing of an existing raised-floor package during a move, upgrade, or decommissioning project.
Raised Computer Floor Finishes
Select from high-pressure laminate, static-control carpet, vinyl, recycled rubber, or bare-steel panels to match performance and design needs.
Data Center Ramps, Steps & Handrails
Custom ramps, steps, and handrails can be configured around the finished raised-floor height and required access or safety conditions.
Raised Floor Understructure
Support options include stringerless and bolted-stringer systems, along with new and pre-owned pedestals and understructure components.
Raised Floor Installation Services
Professional teams can provide on-site installation and de-installation support for raised access-floor projects.
Computer Floor Maintenance, Repair & Cleaning
Maintenance services help repair, clean, and protect raised computer-floor systems over their operating life.
Access Computer Floor Hot Spots
Data-center cooling solutions help address localized hot spots as IT equipment and airflow requirements change over time.
KNOWLEDGE BASE
Raised Access Floor FAQs
Clear answers for product selection, performance, cost, installation, and cable management.
PRODUCT SELECTION
Choosing the right raised floor
Is there a difference between a Raised Access Floor and a Free Access Floor?
In practical use, the terms describe the same type of elevated floor system: a finish floor above a service void for power, data, and other utilities. “Raised Access Floor” is often used when the system is specified for offices and workplaces.
Which floor type and material should I choose?
Choose according to the required wiring capacity, finished floor height, load, acoustic comfort, fire requirements, and future access needs. Concrete-mat systems favor durability and a solid walking feel; lightweight plastic systems reduce structural load; pedestal-supported steel systems provide greater adjustability and deeper service space.
Should an office install a raised access floor?
It is especially useful where layouts, desk positions, or IT equipment change over time. Evaluate usable cable-routing depth rather than finished floor height alone, and allow capacity for future power and network expansion.
Can a seismic-isolation system and a raised floor be installed together?
Yes. A low-profile integrated solution can combine seismic isolation with raised-floor cable management. Confirm the finished height, structural design, and local engineering requirements with the system supplier before specification.
Can a low-profile raised floor be installed while large fixtures remain in place?
It can be possible when the finished floor height still allows cabinet and equipment doors to operate freely. Before installation, measure all clearances at fixture bases, door swings, and service access points.
What should be checked near sprinklers during an office renovation?
Raising the floor changes the clearance between sprinkler heads, ceilings, furniture, and storage. Verify the final height and furniture plan against local fire-safety requirements before selecting the floor system.
SPECIFICATIONS & PERFORMANCE
Comfort, stability, and assurance
What should I do if a raised floor develops movement or instability?
First identify whether the issue is caused by subfloor variation, loose supports, panel damage, or an unsuitable system configuration. Some systems require periodic leveling; fully fixed panel systems may reduce movement. Use a qualified service team for inspection, repair, relocation, or expansion work.
Will a raised floor feel hollow or unstable to walk on?
That depends on the panel core, support method, and installation quality. A floor designed to follow the base slab closely can provide a more solid walking feel, while correctly installed panels and supports minimize noise and rattle.
How can I evaluate product performance?
Request objective performance documentation for load, safety, durability, and relevant market certifications. Compare test methods and approved performance categories rather than relying only on product descriptions.
What warranty should I expect?
Warranty terms vary by manufacturer and system. Review the written coverage, exclusions, expected loading conditions, and who is responsible for inspection or remedial work after installation.
COST BENEFITS
Flexibility over the life of the office
Is wiring easier to change after the floor is installed?
Yes. A planned underfloor service zone makes it easier to add, relocate, or remove outlets and cables as layouts evolve. This can reduce the disruption and recurring cost associated with repeated conventional rewiring.
What are the advantages in a new building?
A low-profile system can help preserve ceiling clearance while maintaining a flexible services zone. The result can be more adaptable layouts, easier cable management, and a cleaner finished office environment.
Is regular maintenance required?
Maintenance needs depend on the panel and support design. Inspect high-traffic areas, rolling-load paths, and any location where panels are frequently lifted. Select a system designed for stable support and clear service access.
Why choose a low-floor design?
Low-profile floors can reduce the visual and physical impact of ramps and preserve more ceiling height. They are particularly useful in renovation projects, accessibility-sensitive areas, and offices with constrained clearances.
CONSTRUCTION
Renovation and fit-out planning
Can a raised floor be installed over a weekend?
For a well-planned office renovation, off-hours installation may be feasible. The schedule should account for furniture moves, existing-cable removal, panel installation, wiring, finish installation, testing, and final workstation setup.
Can partitions be installed above a raised access floor?
Yes, subject to the selected floor system and the partition load. Plan the structural fixing strategy and any requirement to separate or seal underfloor service zones before construction begins.
Can bookcases and other fixtures be anchored through the raised floor?
Where the system and slab condition permit, fixtures can be anchored through the floor to the structural slab. Use a qualified installer or engineer to confirm anchor type, loads, seismic requirements, and panel cut-out details.
WIRING MANAGEMENT
Safe, adaptable underfloor services
What outlet options are available?
Common options include outlets that remain within the floor and outlets that allow services to exit above the floor. Select the format based on desk layout, cable-routing paths, access frequency, and the required surface appearance.
How should office wiring be managed after repeated layout changes?
Maintain an up-to-date office plan and label power, data, and equipment circuits clearly. A well-organized floor system gives staff and contractors a more reliable way to trace and adjust services as the workplace evolves.
What if there is no outlet next to a desk after a layout change?
Plan electrical zones for the expected maximum occupancy, then provide flexible distribution within each zone. A raised floor with sufficient outlet capacity reduces the need for disruptive future wiring work.
How does a raised floor solve exposed office cables?
It relocates power and data services beneath the finished floor, improving appearance and reducing trip hazards. Low-profile systems are often preferred in offices because they preserve headroom while creating usable cable capacity.